BACK TO OUR COOLANTS

RS-52 (R-428A)

PAO (ODP):
0
PCG (GWP): 3607
Flammable:
Non-flammable
Retrofit:
Yes
Compatible lubricants:
Mineral/AB/POE
New installation:
Yes
Temperature range:
Low, Stockings

APPLICATIONS

Cold Truck

Industrial Refrigeration

Commercial Refrigeration

R-428A is a near azeotropic, zero ozone depleting HFC and HC refrigerant gas mixture used as a direct (drop-in) substitute for R-502 and its HCFC substitutes such as R-408A, DI-44, HP80, in a wide variety of medium and low temperature refrigeration applications.

– No harm to the ozone layer, ODP = 0.

– It requires the replacement of mineral or alkylbenzene oil with POE synthetic oil.

– They allow the maintenance of existing equipment.

– In case of leakage, empty and carry out a new full charge.

– Lower discharge temperatures than R-22, which extends the life of the compressor.

– It achieves similar cooling capacity and energy efficiency to R-22 in most systems.

– Global Warming Potential (GWP): 1774

– Boiling point at 1.013 bar (ºC): -43.5

– Temperature glide or glide (ºC): 7,4

– Saturated vapor density at 25ºC (kg/m3): 43.33

– UN NO.: 3340

– Safety classification: A1. Low toxicity and non-flammable.

– Always load in liquid phase.

When R-22 was banned in new equipment, equipment manufacturers took advantage in many cases of the same production lines of R-22 air conditioning equipment to continue manufacturing them for R-407C but this time with synthetic POE oil instead of mineral oil. Not recommended for flooded evaporators or centrifugal compressors.

– 765 kg
– 50 kg
– 20 kg
– 12 kg
– 10 kg
– 5 kg
– 1.8 kg
– 10.9 kg

R-428A is a near azeotropic, zero ozone depleting HFC and HC refrigerant gas mixture used as a direct (drop-in) substitute for R-502 and its HCFC substitutes such as R-408A, DI-44, HP80, in a wide variety of medium and low temperature refrigeration applications.

– No harm to the ozone layer, ODP = 0.

– It requires the replacement of mineral or alkylbenzene oil with POE synthetic oil.

– They allow the maintenance of existing equipment.

– In case of leakage, empty and carry out a new full charge.

– Lower discharge temperatures than R-22, which extends the life of the compressor.

– It achieves similar cooling capacity and energy efficiency to R-22 in most systems.

– Global Warming Potential (GWP): 1774

– Boiling point at 1.013 bar (ºC): -43.5

– Temperature glide or glide (ºC): 7,4

– Saturated vapor density at 25ºC (kg/m3): 43.33

– UN NO.: 3340

– Safety classification: A1. Low toxicity and non-flammable.

– Always load in liquid phase.

When R-22 was banned in new equipment, equipment manufacturers took advantage in many cases of the same production lines of R-22 air conditioning equipment to continue manufacturing them for R-407C but this time with synthetic POE oil instead of mineral oil. Not recommended for flooded evaporators or centrifugal compressors.