APPLICATIONS
Air conditioning
Cold Truck
Industrial Refrigeration
Commercial Refrigeration
R-434A is an almost azeotropic, zero ozone depleting mixture of HFC and HC refrigerant gases, used as a direct (drop-in) substitute for R-22 in equipment with an adjustable expansion system (TXV) with positive, medium and low evaporation temperatures down to -35ºC (-35ºC).
It is the recommended solution to replace R-22 in large air conditioning equipment and refrigeration systems in general. Easy, direct and effective. Compatible with the original system oil. Same cooling capacity as R-22, even at low temperatures. Suitable for flooded systems due to its low temperature creep. May require opening/regulating the expansion valve.
NOTES:
– Fast, simple, economical and efficient replacement.
– No harm to the ozone layer, ODP = 0.
– Compatible with the original system oil.
– They allow the maintenance of existing equipment.
– Equipment can be refilled in case of leakage.
– Although the standard recommendation is not to mix refrigerants, studies show that technically it can be mixed with R-22 in any ratio.
– Discharge temperatures much lower than R-22, which extends the life of the compressor.
– They achieve the same cooling capacity and energy efficiency as R-22.
– Global Warming Potential (GWP): 3238
– Boiling point at 1.013 bar (ºC): -44.9
– Temperature glide or glide (ºC): 1.5
– Saturated vapor density at 25ºC (kg/m3): 53.1
– UN NO.: 1078
– Safety classification: A1. Low toxicity and non-flammable.
– Always load in liquid phase.
– 780 kg
– 50 kg
– 20 kg
– 12 kg
– 10 kg
– 5 kg
– 1.8 kg
– 10.9 kg
Here you can find detailed studies of real examples of the application of this product.
- BRITISH ENERGY – Retrofit of flooded evaporator chillers RS-45
- PATINIUM – Case study with flooded evaporator RS-45
- Ferrocarriles de la Generalitat – RS-45 conversion case study
- RS-45 supermarket conversion case study
- Frutas Roncal-Lana – RS-45 conversion case study
- Avinyó Slaughterhouse – A case study of a RS-45 reconversion.
- QUERCY REFRIGERATION – Retrofit of flooded evaporators with recirculation pump RS-45
R-434A is an almost azeotropic, zero ozone depleting mixture of HFC and HC refrigerant gases, used as a direct (drop-in) substitute for R-22 in equipment with an adjustable expansion system (TXV) with positive, medium and low evaporation temperatures down to -35ºC (-35ºC).
It is the recommended solution to replace R-22 in large air conditioning equipment and refrigeration systems in general. Easy, direct and effective. Compatible with the original system oil. Same cooling capacity as R-22, even at low temperatures. Suitable for flooded systems due to its low temperature creep. May require opening/regulating the expansion valve.
NOTES:
– Fast, simple, economical and efficient replacement.
– No harm to the ozone layer, ODP = 0.
– Compatible with the original system oil.
– They allow the maintenance of existing equipment.
– Equipment can be refilled in case of leakage.
– Although the standard recommendation is not to mix refrigerants, studies show that technically it can be mixed with R-22 in any ratio.
– Discharge temperatures much lower than R-22, which extends the life of the compressor.
– They achieve the same cooling capacity and energy efficiency as R-22.
– Global Warming Potential (GWP): 3238
– Boiling point at 1.013 bar (ºC): -44.9
– Temperature glide or glide (ºC): 1.5
– Saturated vapor density at 25ºC (kg/m3): 53.1
– UN NO.: 1078
– Safety classification: A1. Low toxicity and non-flammable.
– Always load in liquid phase.
– 780 kg
– 50 kg
– 20 kg
– 12 kg
– 10 kg
– 5 kg
– 1.8 kg
– 10.9 kg
Here you can find detailed studies of real examples of the application of this product.
- BRITISH ENERGY – Retrofit of flooded evaporator chillers RS-45
- PATINIUM – Case study with flooded evaporator RS-45
- Ferrocarriles de la Generalitat – RS-45 conversion case study
- RS-45 supermarket conversion case study
- Frutas Roncal-Lana – RS-45 conversion case study
- Avinyó Slaughterhouse – A case study of a RS-45 reconversion.
- QUERCY REFRIGERATION – Retrofit of flooded evaporators with recirculation pump RS-45
Related products
RS-70 (R-453A)
GWP=1765
The best drop-in substitute for R-22 on the market
R-422D
GWP=2729
Drop in of R-22
RS-70
The best drop-in substitute for R-22 on the market
RS-45 (R-434A)
GWP=3245
Drop-in of R-22. Special for flooded systems