BACK TO OUR COOLANTS

R-507A

PAO (ODP):
0
PCG (GWP): 3985
Flammable:
Non-flammable
Retrofit:
Yes
Compatible lubricants:
POE
New installation:
Yes
Temperature range:
Low, Stockings

APPLICATIONS

Cold Truck

Industrial Refrigeration

Commercial Refrigeration

R-507A is an azeotropic, zero ozone depleting HFC refrigerant gas mixture used in new medium and low temperature refrigeration equipment. It is also an indirect substitute (retrofit), in equipment that had previously worked with R-502 and its HCFC substitutes such as R-408A, DI-44, HP80.

R-507A is a long-term substitute refrigerant for installations with medium and low refrigeration temperatures that previously would have used R-502 or R-22. Its physical, thermodynamic and operational properties are very similar to those of R-502. Discharge temperatures are lower than R-502. In some working conditions, the cooling capacity is even higher than R-502 but at the same time with a slightly lower coefficient of performance.

Applications:

– Refrigerated warehouses.

– Refrigerated showcases.

– Ice cream machines.

– Ice rinks.

– Cold storage rooms.

– Refrigerated transport.

– Cold beverage dispenser.

– Tunnel freezers.

– Fishing boats.

– Flooded systems.

– No harm to the ozone layer, ODP = 0.

– Only compatible with POE synthetic oils.

– Equipment can be refilled in case of leakage.

– Lower discharge temperatures than R-22 and R-502, which extends the life of the compressor.

– Cooling capacity and energy efficiency very similar to R-502.

– Superior cooling capacity and energy efficiency similar to R-22.

– Global Warming Potential (GWP): 3985

– Boiling point at 1.013 bar (ºC): -46.7

– Temperature glide or glide (ºC): 0

– Saturated vapor density at 25ºC (kg/m3): 66.64

– UN NO.: 1078

– Safety classification: A1. Low toxicity and non-flammable.

– Always load in liquid phase.

– 740 kg
– 50 kg
– 20 kg
– 12 kg
– 10 kg
– 5 kg
– 1.8 kg
– 0.8 kg
– 10.9 kg

R-507A is an azeotropic, zero ozone depleting HFC refrigerant gas mixture used in new medium and low temperature refrigeration equipment. It is also an indirect substitute (retrofit), in equipment that had previously worked with R-502 and its HCFC substitutes such as R-408A, DI-44, HP80.

R-507A is a long-term substitute refrigerant for installations with medium and low refrigeration temperatures that previously would have used R-502 or R-22. Its physical, thermodynamic and operational properties are very similar to those of R-502. Discharge temperatures are lower than R-502. In some working conditions, the cooling capacity is even higher than R-502 but at the same time with a slightly lower coefficient of performance.

Applications:

– Refrigerated warehouses.

– Refrigerated showcases.

– Ice cream machines.

– Ice rinks.

– Cold storage rooms.

– Refrigerated transport.

– Cold beverage dispenser.

– Tunnel freezers.

– Fishing boats.

– Flooded systems.

– No harm to the ozone layer, ODP = 0.

– Only compatible with POE synthetic oils.

– Equipment can be refilled in case of leakage.

– Lower discharge temperatures than R-22 and R-502, which extends the life of the compressor.

– Cooling capacity and energy efficiency very similar to R-502.

– Superior cooling capacity and energy efficiency similar to R-22.

– Global Warming Potential (GWP): 3985

– Boiling point at 1.013 bar (ºC): -46.7

– Temperature glide or glide (ºC): 0

– Saturated vapor density at 25ºC (kg/m3): 66.64

– UN NO.: 1078

– Safety classification: A1. Low toxicity and non-flammable.

– Always load in liquid phase.

Scroll to Top