BACK TO OUR COOLANTS

R-410A

PAO (ODP):
0
PCG (GWP): 2088
Flammable:
Non-flammable
Retrofit:
No
Compatible lubricants:
POE
New installation:
No
Temperature range:
High

R-410A is a near azeotropic HFC refrigerant gas blend developed as a zero ozone depleting substitute for R-22 in new air conditioning equipment. Positive evaporation temperatures.

It is the preferred choice internationally for new air conditioning equipment, heat pumps, etc. Unlike R-22, R-410A works at much higher pressures and only with POE synthetic oil. The great advantage of R-410A is its high cooling capacity, which can be 50% higher than R-22. For this reason, smaller components can be used and more compact machines can be built compared to R-22. Copper fittings, piping, valves, compressors, etc. must be designed to withstand the increased pressure of R-410A.

Due to its working pressures, R-410A is not suitable for retrofitting existing equipment with R-22. For retrofitting R-22 equipment, we recommend the RS-70 (R-453A) drop-in replacement. For retrofitting existing equipment with R-410A, we recommend the RS-53 (R-470A) drop-in replacement.

No harm to the ozone layer, ODP = 0.

– Only compatible with POE synthetic oils.

– Equipment can be refilled in case of leakage.

– Cooling capacity and working pressure much higher than R-22.

– Global Warming Potential GWP (GWP) = 2088

– Boiling point at 1,013 bar (ºC): -51,58

– Temperature glide or glide (ºC): 0.1

– Saturated vapor density at 25ºC (kg/m3): 61.5

– UN NO.: 1078

– Safety classification: A1. Low toxicity and non-flammable.

– Always load in liquid phase.

– 790 kg
– 50 kg
– 20 kg
– 11 kg
– 10 kg
– 5 kg
– 1.8 kg
– 0.8 kg
– 11.3 kg

R-410A is a near azeotropic HFC refrigerant gas blend developed as a zero ozone depleting substitute for R-22 in new air conditioning equipment. Positive evaporation temperatures.

It is the preferred choice internationally for new air conditioning equipment, heat pumps, etc. Unlike R-22, R-410A works at much higher pressures and only with POE synthetic oil. The great advantage of R-410A is its high cooling capacity, which can be 50% higher than R-22. For this reason, smaller components can be used and more compact machines can be built compared to R-22. Copper fittings, piping, valves, compressors, etc. must be designed to withstand the increased pressure of R-410A.

Due to its working pressures, R-410A is not suitable for retrofitting existing equipment with R-22. For retrofitting R-22 equipment, we recommend the RS-70 (R-453A) drop-in replacement. For retrofitting existing equipment with R-410A, we recommend the RS-53 (R-470A) drop-in replacement.

No harm to the ozone layer, ODP = 0.

– Only compatible with POE synthetic oils.

– Equipment can be refilled in case of leakage.

– Cooling capacity and working pressure much higher than R-22.

– Global Warming Potential GWP (GWP) = 2088

– Boiling point at 1,013 bar (ºC): -51,58

– Temperature glide or glide (ºC): 0.1

– Saturated vapor density at 25ºC (kg/m3): 61.5

– UN NO.: 1078

– Safety classification: A1. Low toxicity and non-flammable.

– Always load in liquid phase.

Scroll to Top